are available from 9 KHz to 2.5 GHz, as well as custom products for microwave applications. |
|
 |
 |
HP3708A vs CNG-70/140 Comparison |
 |
 |
|
Micronetics offers a functional replacement for the obsolete HP 3708A Noise and Interference Test Set. Micronetics' CNG 70/140, features, better EbNo accuracy, more functionality and an intuitive graphical user interface. It also features built-in math functions, eliminating the need to perform external calculations.
A side-by-side comparison of some of the specifications and functions are outlined below.
Specs
 |
HP 3708A
 |
CNG 70/140
 |
| Functions |
C/N, No, EbNo |
C/N, C/I, C/No, Eb/No, No |
| Frequency |
10 - 200 MHz |
50 - 180 MHz |
| Input Range |
-40 to +20 dBm |
-40 to +20 dBm |
| Carrier Path Loss |
0 dB |
-7 dB (no amp in carrier path) 0 dB (stnd. option) |
C/N Accuracy
 |
0.5 to 0.3 dB dependent on C/N level |
0.15 dB RSS
 |
| Carrier Attenuator |
n/a |
0 - 60 dB in 0.1 dB steps (stnd. option) |
| Constant Noise Mode EbNo vs BER |
n/a |
With Make before Break (stnd. option) |
| Injector Port |
Yes |
Yes (stnd option) |
| External Filter Capability |
Yes |
Optional |
| Display |
Alpha Numeric |
Color LCD |
| Bus Control |
HP-IB
 |
GP-IB or RS232 |
| Bandwidth Entry |
n/a |
Yes |
| Annual Calibration |
Manual |
Built-in Software |
| Total Noise Power Status |
n/a |
On Front Panel and via GPIB |
Additional product specifications
back to test equipment page
Information found within this document is subject to change without notification. HP 3708A Noise and Interference Test Set and other product and company names mentioned herein are the trademarks or registered trademarks of their respective companies. 9/01/01
|
|